autochim - Analysis and detection of gas - Flame detection autochim - Analysis and detection of gas - Flame detection
 Analysis and detection of gas - Flame detection Performance Guarantee
 Company profile
 Activities
 Products
 Services

 Products: 

Measure with the emission

 Previous   Next 


Many industries, because of their their process, reject with the atmosphere of many pollutants: gases with the effect of greenhouse or pollutant gases for the man.

In order to protect the environment, they must control their rejection, in a continuous or specific way.

autochim proposes portable anlyseurs or at station fixes off-set or in-situ based on the following techniques:

  • Detection by flame ionization for the measurement of hydrocarbons and COV total.

  • Infra red analyzers for the measurement of CO, CO2? SO2, Nox, HCI, NH3…

  • Ultraviolet analyzer for the measurement of NO, NO2? F2, C I2...

  • Analyzer by acoustic photo spectroscopy for the specific analysis of certain COV in the air .

  • Liquids portable Chromatograph by photo ionization for the analysis of the COV.

Applications:

  • Power stations.

  • Cement factories.

  • Paper mill  usiones.

  • Refineries.

  • Chemical refineries.

  • Controls emissions and pollutionc atmospheric.

  • Thermal control.

  • Incineration of solvents.

  • Measures of DREGS.

  • Followed of process.

Principle of the analysis by flame ionization:

The detector with flame ionization heated with 180°C transforms a hydrocarbon content contained in a sample into electric signal thanks to the contribution of hydrogen and air exept of hydrocarbons. When the sample arrives to the flame, the hydrocarbon molecules undergo the hydrocarbon molecules undergo a cracking then oxidize in the presence of oxygen and of ions CHO+ are formed. autochim can propose in this range various versions:

  • Portable analyzer equipped with all the accessories necessary (heated line, bottles,filter...).

  • Analyzer rackable or gone up in panel using the system of ejector with air replacing the pump of aspiration thus.

  • Analyzer in-situ not requiring any preliminary treatment of sample and allowing a response time lower than 1,5 second.

Analyze in-situ:

Most pollutants we have to measure absorb the light in IR or in UV to measure their concentrations amounts measuring the quantity of light absorptive by gas with a specific wavelength. In order to reduce the costs of maintenance of these analyzers, autochim proposes a broad range of apparatuses in-situ. This method consists in measuring uninterrupted the concentrations directly in the chimney, thus eliminating any system of sampling requiring a regular maintenance.

The main advantages are:

  • Two annual maintenance actions max.

  • No modification of the sample.

  • Up to 6 made up measured with the same analyzer automatic.

  • Self-zero and calibration with a gas certified.

  • No problem of alignment since it acts of only one probe of measurement.

Specific COV.

If a specific analysis of some made up organics volatile is required, we can provide you portable equipments or in station fixes in order to take these measurements: portable chromatograph by photo ionization or analyzer by acoustic photo spectroscopy. These equipments can be used by a service provider or the industrialist.


 Previous   Next 